Operation
To print the Sensitivity voltages of all the
smoke detectors for the specified module,
use the arrow keys to cause the S in SENS
to blink and press PRINT. The System
prints those sensitivity voltages in a format
similar to the following (ND = No Device, or
device not a smoke detector):
SENSITIVITY VOLTAGES FOR MODULE 1
1- 2.75
2- 2.62
3- ND
4- ND
5- ND
6- ND
7- ND
10- ND
8- ND
9- ND
11- ND
12- ND
13- ND 14- ND 15- ND
(To end a menu session and return to the
Main Menu or to leave the menu at any time,
press the Up arrow key to go backward one
menu each time.)
List: Temp
Use List Temp to display the current
temperature on the LCD display at the
location where the detector is installed.
From the List menu use the left or right
arrow key to cause the T in Temp to start
blinking:
LIST: TEMP
Press ENTER to select List Temp. The
System asks you for a module and device
number:
Type In Module & Device:
Type the three-digit module number and
three-digit device number using the nu-
meric keypad and press ENTER.
If the device is not installed or is not an
FP-11 or FPT-11, the system displays
following message:
Not Applicable or No Device:
If the device is an FP-11 or FPT-11, the
temperature is displayed in the following
format:
001-001 25 DEG C / 77 DEG F
Press NEXT to display the temperature of
the FP-11 or FPT-11 at the next higher
address in the same loop.
To leave the Temp menu without going
through all subaddresses, press the Up
arrow key. The System displays the List
menu.
List: Module Type
Use the List Mod_type to show the type of
a particular module.
From the List menu use the Left or Right
arrow key to cause the M in MOD TYPE to
start blinking:
LIST: VOLTAGES MOD TYPE SENSTVTY
(If you press HELP at this point, the System
explains this function:
SHOW THE TYPE OF MODULE
Press HELP again to return to the List
menu.)
Display the Module Type of One Module
Press ENTER when the M in MOD_ TYPE
is blinking. The System asks you for a
module number:
TYPE IN MODULE NUMBER:
Type the three-digit module number using
the numeric keypad and press ENTER.
(Enter the leading zeros.) The System
displays the module type for the module
number specified:
MOD 074 TYPE: CZM4
If you press NEXT, the System displays the
module type for the next module number in
the sequence:
MOD 075 TYPE: ALD
NOTE:
If you enter a module number not
assigned in CSG-M, the System
displays:
NO MOD ASSIGNED
Summary of Contents for MXL-IQ
Page 50: ...2 20 Installation ...
Page 126: ...A 2 Appendix A ...
Page 128: ...B 2 Appendix B ...
Page 138: ...F 4 Appendix F ...
Page 140: ...G 2 Appendix G ...
Page 142: ...H 2 Appendix H ...
Page 154: ...K 2 Appendix K ...
Page 162: ...L 8 Appendix L ...
Page 166: ...M 4 Appendix M ...
Page 168: ...N 2 Appendix N ...
Page 178: ...Index 6 Index ...