Installation
5.2 Layout
BW500 and BW500/L
24
Operating Instructions, 12/2016, A5E33482052-AD
WARNING
•
All field wiring must have insulation suitable for at least 250 V.
•
DC input terminals shall be supplied from a source providing electrical isolation between
the input and output, in order to meet applicable safety requirements of IEC 61010-1.
•
Relay contact terminals are for use with equipment having no accessible live parts and
wiring having insulation suitable for at least 250 V. The maximum allowable working
voltage between adjacent relay contact shall be 250 V.
•
The non-metallic enclosure does not provide grounding between conduit connections.
Use grounding type bushings and jumpers.
Please note that the DC version of this layout will appear slightly differently.
Mounting the Enclosure
1.
Remove the lid screws and open the lid to reveal the mounting holes.
2.
Mark and drill four holes in the mounting surface for the four screws (customer supplied).
3.
Fasten with a long screwdriver.
①
Mounting holes
Note
•
Recommended mounting: directly to wall or to electrical cabinet back panel with #6
screws
•
If alternate mounting surface is used, it MUST be able to support four times the weight of
the unit.
Summary of Contents for Milltronics BW500
Page 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Page 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Page 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Page 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Page 48: ......
Page 154: ......
Page 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Page 219: ......