Parameters
12.6 Linearization Parameters (P390 - P392)
BW500 and BW500/L
172
Operating Instructions, 12/2016, A5E33482052-AD
12.6
Linearization Parameters (P390 - P392)
These parameters are used to compensate for non-linear response of the weighing system to
the BW500 and BW500/L. Refer to
Linearization
for execution, and example on the use of these
parameters.
Note
In the case of multispan operation, the linearizer is applied to all spans.
12.6.1
P390 Linearizer
Enables or disables the linearization function.
Entry:
0 = OFF
f
1 = ON
12.6.2
P391 Linearizer Load Points
Enters the load values, in units of P017, for the point selected, points 1 to 5 (P391-01 to -05) (
f
=
0.00, 150 % max.)
12.6.3
P392 Linearizer Compensation %
Enters the compensation value, in percent, for the point selected, point 1 to 5 (P392-01 to
−
05) (
f
= 0.00), range is -150 to 150 %.
12.6.4
P398-01 Moisture Content
Factors out moisture component of load, rate and total for all multispans selected. The factored
values are meant to report the dry mean values of the material being conveyed (
f
= 0.00)
Enter the moisture content in % weight or mA Input Value
1)
.
1)
BW500/L will allow manual entry of a moisture content.
12.6.5
P398-02 Moisture Content
Allows moisture content P398-01 to be scaled to maximum value.
Enter the moisture content in % weight (maximum value 20 mA)
Note
Not available with BW500/L.
Summary of Contents for Milltronics BW500
Page 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Page 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Page 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Page 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Page 48: ......
Page 154: ......
Page 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Page 219: ......