Certification
14.3 Certification Printing
BW500 and BW500/L
198
Operating Instructions, 12/2016, A5E33482052-AD
14.3
Certification Printing
Certification printing is allowed if the following conditions are met:
●
certification switch is set
●
rate is below 2 %
●
a communications port has been programmed for a printer
The printout must consist of the following:
●
Date: YYYY-MM-DD
●
Time: HH:MM:SS
●
Instrument ID#: Belt Scale serial number
●
Units: Units set in P005
●
Start Total: End total of previous print
●
End Total: Accumulated totalizer including Start Total
●
Net Total: End total minus Start Total
If a power failure occurs during totalization, power failure indicator “PF” will be printed in the
middle of a new line, even if it has been cleared from the screen. “PF” will be cleared from the
screen after printing.