PID Control
9.5 Programming
BW500 and BW500/L
118
Operating Instructions, 12/2016, A5E33482052-AD
Note
For the mA input:
•
mA input 1 is an external signal normally reserved for controller 1. The signal is input at
terminals 5 and 6 on the mA I/O board.
•
mA input 2 is an external signal normally reserved for controller 2. The signal is input at
terminals 7 and 8 on the mA I/O board.
P250-01 mA Input Range
E
Select 1- 0 to 20, 2-4 to 20
2
Select the appropriate range for the mA input signal.
P255-01 mA Input Function
E
Select: 0, 1-PID SP, 2-PID PV
0
Assign either 1: PID setpoint, or 2: process variable as the function of the mA input.
P401-01 PID Update Time
E
Readings between PID Updates
1
Enter the value, e.g. nominal value of 1.
P402 Process Variable Source
E
1- Rate, 2-Load, 3-mA In
Select the source. Rate and load are internal values.
P405-01 Proportional Term
E
Enter
0.40
Enter the value for the proportional term, for example: nominal value of 0.4.
P406-01 Integral Term
E
Select 1- 0 to 20, 2-4 to 20
0.2
Enter the value for the integral term, for example: nominal value of 0.2.
P407-01 Derivative Term
E
Enter
0.05
Enter the value for the derivative term, for example: nominal value of 0.05.
Summary of Contents for Milltronics BW500
Page 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Page 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Page 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Page 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Page 48: ......
Page 154: ......
Page 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Page 219: ......