Register Map for BW500 and BW500/L
Map Legend
Description
Type:
Arbitrary classification of registers.
Description:
Brief description or title of associated register.
Start:
Provides the starting address for the register(s)
where the parameter values are to be read from
or written to.
Number R:
The number of registers required to read or write
the complete parameter value. Where the num-
ber of registers (6) are addressed in incrementing
sequence from the start register.
Parameter Values:
Refer to
Parameter Values.
Read:
Identifies the read / write capability for the regis-
ter being addressed.
Reference:
Provides reference documentation for the register
being addressed.
Type
Description
Start
# R
Parameter
Values
Read
Reference
Format
Format
Word for 32
bit variables
40,062
1
0 - 1
r/w
Refer to
Modbus
Register
Map (cont’d)
section
given below.
ID
Device Iden-
tifier
40,064
1
2
r
Refer to
Modbus
Register
Map (cont’d)
section
given below.
Handshak-
ing Area
(Parameter
Access)
Parameter
40,090
1
0-999
r/w
Refer to the
Modbus
Register
Map (cont’d)
section
given below.
Primary
Index
40,091
1
0 - 9
r/w
Secondary
Index
40,092
1
0 - 9
r/w
Format
Word
40,093
1
bit mapped r/w
Read Value
(word 1)
40,094
2
32 bits
r
Write Value
(word 1)
40,096
2
32 bits
r/w
Date and
Time
a)
YYYY
41,000
1
1996-2069
r/w
Refer to the
Date and
MM
41,001
1
1 - 12
r/w
Summary of Contents for Milltronics BW500
Page 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Page 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Page 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Page 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Page 48: ......
Page 154: ......
Page 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Page 219: ......