Installation
5.4 Interconnection
BW500 and BW500/L
32
Operating Instructions, 12/2016, A5E33482052-AD
5.4.4
Scale - Four Load Cells
①
Customer junction box
②
Integrator
③
Load cell excitation
④
Load cell inputs
Where separation between the BW500 and belt scale exceeds 150 m (500 ft), or legal for trade
certification:
1.
remove jumpers from BW500 terminal 11/12 and 13/14
2.
run additional conductors from:
BW500 terminal 12 to scale 'red'
BW500 terminal 13 to scale 'blk'