Start Up
6.4 Load Cell Balancing
BW500 and BW500/L
60
Operating Instructions, 12/2016, A5E33482052-AD
Load Cell Balancing A & B
Load cells are now balanced
Balancing the load cells requires a subsequent zero and span calibration
If four load cell scale, press the following key to continue:
P295 Load Cell Balancing:
Select: 1-A&B, 2-C&D
V
1
Press the following key:
P295 Load Cell Balancing:
Select:1-A&B, 2-C&D
E
1
Press the following keys:
Load Cell Balancing C & D
Place weight at cell D and press ENTER