12.3 mA I/O Parameters (P200 - P220)
BW500 and BW500/L
166
Operating Instructions, 12/2016, A5E33482052-AD
Value
Function
Symbol
Description
14
a)
initiate online calibra-
tion:
momentary closure of
the input contact initi-
ates online calibration
15
a)
accept new online cali-
bration span:
momentary closure of
the input contact ac-
cepts the online calibra-
tion deviation
16
a)
auxiliary speed sensor
for differential speed
detection
a)
Not available with BW500/L.
Entry:
Note
Before you can use Online Calibration, P100, P255, P355, P356, and P357 must be set up.
0 = OFF
f
1 = alternate display
2 = reset totalizer 1
3 = zero
4 = span
5 = print
6 = multispan selection
1) 2)
7 = reserved
2)
8 = reset batch
2)
9 = PID freeze
2)
10 = PID setpoint source
2)
11 = PID mode
2)
12 = external alarm
13 = remote communication write
14 = Initiate Online Calibration
2)
15 = Accept new online calibration span
2) 3)
16 = Auxiliary speed sensor
2)
1)
If the BW500 is programmed for multispan operation, the auxiliary input contact state
determines the multispan number (equivalent to P365). Input 1 is reserved for multispan 1 and 2
selection. Input 2 is reserved for multispan 3 and 4 selection. Input 3 is reserved for multispan 5
to 8 selection.
2)
Not available with BW500/L
Summary of Contents for Milltronics BW500
Page 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Page 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Page 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Page 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Page 48: ......
Page 154: ......
Page 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Page 219: ......