Parameters
12.5 Online Calibration Options (P355 - P358)
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
169
12.5.3
P357 Online Calibration Limits
Use to enter the weigh bin limit settings.
P357.1 MAX LIMIT, range 0.0 to 100.0 (
f
= 0%)
P357.2 HIGH LIMIT, range 0.0 to 100.0 (
f
= 0%)
P357.3 LOW LIMIT, range 0.0 to 100.0 (
f
= 0%)
12.5.4
P358 Online Calibration Activation
Initiates online calibration.
Entry:
0 = OFF
f
1 = ON
12.5.5
P359 Factoring
Factoring is used as a method of calculating the value of the test load (P017) to a new test
reference; either: weight, or chain. The task is performed only for the weight or chain relevant for
the multispan selected, if applicable.
Entry:
1 = weight (
f
= 1)
2 = chain
Refer to Recalibration (Page 67) for execution of the factoring procedure.
Note
Totalization is halted during the factoring procedure, and resumed only upon return to the
RUN mode.
12.5.6
P360 Calibration Duration
Sets the number of whole belt revolutions to be used during a zero or span calibration.
Enter number of belt revolutions, range 1 to 99. For belt scale applications 1 belt revolution or 2
minutes, whichever is longer; for weghfeeder applications 3 belt revolutions or 5 minutes,
whichever is longer.
Summary of Contents for Milltronics BW500
Page 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Page 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Page 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Page 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Page 48: ......
Page 154: ......
Page 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Page 219: ......