The user is offered a text-driven format for
commissioning, parameterising, configuring and
operating the inverter. The following features are
included:
•
Illuminated high resolution LCD screen
with adjustable contrast.
•
7
languages.
•
Central device for up to 31 inverters which
are networked together via USS.
•
Up to 10 parameter sets can be stored in
non-volatile memory for uploading and
downloading between the clear text
operator panel and the drive.
•
Help texts for diagnosing faults.
•
Isolated RS232 interface for connecting to
a PC.
Dimensions H x W x D
130 mm x 73 mm x 40 mm
Current drain at 5 V
250 mA
Degree of protection
IP 54
Maximum cable length
5m
Table 1: Technical Data
LCD
Display
FORWARD / REVERSE
Button
6
RUN
Button
3
STOP
Button
4
RUN / STOP
Inducator
2
JOG
Button
1
UP / INCREASE
Frequency
7
DOWN / DECREASE
Frequency
8
Parameterisation
Button
9
P
Jog
Menu
RUN
STOP
MENU
Button
5
P000 RUNNING
→
RPM=1250
F=50.00Hz
I=1.5A M=125% P
↕
Indications as to which keys to use are shown in
the right hand column of the screen.
All the main functions are accessible from the
main menu screen:
OPERATE
UPREAD
M
DIAG.
DOWNLOAD
PARAMS
LANGUAGE
P
MODE
CONFIG.
Operating display
Diagnosis of
drive faults
Parameterise
drive
Mode selection for module:
Local, Master, Internal, RS232-RS485 convert
Upread parameter sets
from drive to module
Download parameter sets
from module to drive
Language selection
Configure module features:
Backlight, Contrast, Large
Numbers, Cursor, Help, Reset
Main Menu Screen
Pressing the Menu and
"
keys simultaneously
causes a help screen, displaying the key features
of the Clear Text display module, to appear.
On power-up, unless configured otherwise, the
panel will show the Operating Display.
STOPPED
M
P000
S=50.00Hz
I=0.0A
RPM=0
P
V=0.0V
Drive status:
Stopped, Running,
Fault, Warning
Direction of
motor rotation
Output frequency
(alternating with setpoint
when drive stopped)
Actual motor speed
Motor voltage
Motor
current
Operating Display when in Local mode.
M
B
RUNNING
P
F=50.00Hz
Drive status:
Stopped, Running,
Fault, Warning
Output frequency
(alternating with setpoint
when drive stopped)
Direction of
motor rotation
Drives present on the USS Bus
in this case 0, 7 and 16, selectable
with arrow keys
Enable broadcast function
to start and stop all drives
on bus
Operating Display when in Master mode.
The status LED indicates whether the drive is
running. When the LED is green, the drive is
running and when it is red the drive is stopped.
When accessing drive parameters, help texts are
associated with the parameter and the parameter
values.
Shows that internally
stored parameter set
is being accessed
Text describing
selected parameter
I
PARAMS All
M
P051=
1
M
SELECT DIG I/P 1
P
run right h
Parameter
number
Indicates that higher and lower
parameter values are available
Text describing
selected value
Parameter
access
Parameter group:
All, General, Motor Plate,
Ramping, PID, Setpoint, Freq.
I/O, Comms. User Interface,
Setup, Changed from default