Setting and controlling the dome camera
46
Building Technologies
048_CCDA1445_A6V10257135_V1.0_en
Fire Safety & Security Products
20.08.2009
9.3.2.3
Setting the pattern tour
4 tours can be recorded individually, tours including ZOOM IN, ZOOM OUT,
panning and tilting. Once stored tours can be recalled and repeated continuously
or individually. Each tour can record up to 6 min.
To set the PATTERN TOUR:
1.
Start record: Enter 87, 88, 89, 90 "MEM".
2.
Stop record: Enter 91 "POS" to stop record.
3.
Start play: Enter 87, 88, 89, 90" POS".
9.3.2.4
Setting scan limit stops
Z
The menu item SCAN LIMIT STOPS is set to ON. See page [
J
59]
1.
Setup the camera for the left limit stop.
2.
Enter “81” on the keyboard.
3.
Press <MEM>.
Ö
SCAN LEFT LIMIT will be displayed on the screen.
4.
Manually set the camera for the right limit stop.
If the right limit stop is less than 10 degrees from the left limit stop, NO ACCEPT
will be displayed on the screen.
5.
Enter “82” on the keyboard.
6.
Press <MEM>.
Ö
SCAN RIGHT LIMIT will be displayed on the screen.
Ö
Setting scan limit stops is finished.
9.3.2.5
Setting manual limit stops
Z
The menu item MANUAL LIMIT STOPS is set to ON. See page [
J
59]
1.
Setup the camera for the left limit stop.
2.
Enter “79” on the keyboard.
3.
Press <MEM>.
Ö
MANUAL LEFT LIMIT will be displayed on the screen.
4.
Manually set the camera for the right limit stop.
If the right limit stop is less than 10 degrees from the left limit stop, NO ACCEPT
will be displayed on the screen.
5.
Enter “80” on the keyboard.
6.
Press <MEM>.
Ö
MANUAL RIGHT LIMIT will be displayed on the screen.
Ö
Setting manual limit stops is finished.