8.2.3.5
Wall mount with junction box (CCDA1425-WMJ)
CAUTION
Danger of damage/injuries from assembly falling down
z
When using outdoor housing ensure that the safety wire of the dome housing
is always fixed firmly to the mount to prevent unit from falling down.
z
Check the assembly by pulling. The assembly should not come apart.
CAUTION
Damage due to water entering the unit
If the outdoor housing is not mounted correctly, water may enter and damage the
dome camera.
z
Use the PG gland for all kind of mounts to ensure improved IP66 of housing.
z
Use waterproof adhesive to wind around the connections (threads) between
pipes to prevent water from entering.
z
Insert the pipe screw (NPT ¾”-14) in one of the two holes that are not used.
z
There are 2 plastic cable glands enclosed with the wall mount with junction
box. One of it with 4 holes for Ø4~7mm cables (It’s assembled on the bottom
end of junction box), the other one is with 1 hole for Ø10~16mm cable.
There’re relative sealed pins for each hole. To remain waterproof, please put
the sealed pins in the hole without cable.
z
All the appliances’ cable should be fed in the junction box through the bottom
end to remain waterproof.
Installation of wall mount with junction box