Installation
14
Building Technologies
048_CCDA1445_A6V10257135_V1.0_en
Fire Safety & Security Products
20.08.2009
8
Installation
CAUTION
Danger of damage/injuries from dome camera falling down
z
Ensure that the safety wire (located in the dome base) is engaged.
z
Align notch with "OPEN" arrow and turn dome until notch meets arrow in
"LOCKED" position.
CAUTION
Danger of damage/injuries from assembly falling down
z
When using outdoor housing ensure that the safety wire of the dome housing
is always fixed firmly to the mount to prevent unit from falling down.
z
Check the assembly by pulling. The assembly should not come apart.
22
0
16
4
134
Unit:mm
1
4
3
2
5
COM
Alarm1
Alarm2
Alarm3
N.O(Normal Open)
Alarm4
GND
N.C(Normal Close)
Data+
Data-
7
6
9
8
11
5
12
10
13
14
1.
Setup the DIP switch on Dome base and Dome drive to select baud rate,
address and protocol (see Installation & Configuration Manual for details).
2.
Refer to Fig. A to install the dome base and dome drive. Connect the safety
wire (3) to the hook (2) of the dome base (1) carefully to prevent the dome from
dropping.
3.
To lock the dome drive (4) to the dome base, line up the notch (11) to the right
arrow on the label (12) then turn dome drive to right with both hands (see figure
C) till the notch lines up to left arrow.
4.
Connect BNC connector: connect BNC extension cable (10) to BNC connector
(9).
5.
Connect video cable: connect BNC VIDEO OUT cable (10) to the monitor with
a coax cable.
6.
Fix video cable on BNC connector holder (6).
7.
Connect RS485 interface: Connect RS485 wire from control device to the
Data+/Data- terminal (7).