Installation
15
Building Technologies
048_CCDA1445_A6V10257135_V1.0_en
Fire Safety & Security Products
20.08.2009
8.
Connect control signal: 4 alarm IN and 2 alarm OUT terminals are available (7).
9.
Connect power supply (8): Only 24 V AC ±10 % power can be supplied for this
product, voltage over this range will damage the product.
10.
Connect power source to power terminal.
8.1
Wiring the dome
CAUTION
Damage to the plug-type power supply due to overload
When using a plug-type power supply unit with a power rating of less than 35 W
the unit may be damage due to overheating.
z
Make sure to connect to a power supply that allows for at least 35 W
consumption.
1
2
3
4
5
6
7
12
0¢
X
120¢X
G
N
D
24
V
A
C
1 Extension BNC cable
2 BNC connector holder
D-
Data input RS485 (- / B)
3 Terminal control (RS485)
D+
Data input RS485 (+ / A)