Setting and controlling the dome camera
43
Building Technologies
048_CCDA1445_A6V10257135_V1.0_en
Fire Safety & Security Products
20.08.2009
9.2
Protocol select
NOTICE
Please ensure to set the appropriate camera address and baud rate using the DIP
switches.
Make sure that the RS485 bus termination is only switched on at the last device
on the RS485 bus. On all other dome devices, the termination must be set to "off".
2
1
1
Switch for termination
OFF: RS485 bus termination off (default)
ON: RS485 bus termination on (only last device)
2
Protocol select (see table below)
Protocol Pelco P
Pelco D
VCL
Vicon
Kalatel
bit 2
OFF
ON
OFF
ON
OFF
bit 3
OFF
OFF
ON
ON
OFF
bit 4
OFF
OFF
OFF
OFF
ON
bit 5
OFF
OFF
OFF
OFF
OFF
Protocol Ernitec
MOLYNX D
SENSORMATIC FIELDBUS
SIEMENS
bit 2
OFF
OFF
ON
ON
ON
bit 3
ON
OFF
OFF
OFF
ON
bit 4
ON
OFF
ON
OFF
ON
bit 5
OFF
ON
OFF
ON
OFF
Protocol select