Installation
32
Building Technologies
048_CCDA1445_A6V10257135_V1.0_en
Fire Safety & Security Products
20.08.2009
1
Allen key
2
Rubber cap
3
Expansion anchor
4
Hexagon head nut
5
Pendant mount
6
Safety wire screw
7
Outdoor housing
Unit: mm
350
165
208
11
2
154
Ø 12
Ø 42
Dimensions of pendant mount
1.
Paste the mounting template on the ceiling.
2.
Drill 4 holes into the ceiling with Ø ⅜” (9.5 mm), depth 1½” (40 mm).
3.
Use a hammer to put an expansion anchor into each hole just drilled.
4.
Attach the pendant mount to the ceiling, then fasten the 4 hexagon head nuts
securely.
5.
Pull the rubber cap onto the mount pipe.
6.
Attach an outdoor housing to the pendant mount.
7.
Use an Allen key to fasten the fixing screw to prevent the outdoor housing from
falling.
8.
Fix the safety wire of the outdoor dome housing to the mount using the safety
wire screw.
9.
Place the rubber cap in the proper position.
Ö
The installation is completed.