Setting and controlling the dome camera
42
Building Technologies
048_CCDA1445_A6V10257135_V1.0_en
Fire Safety & Security Products
20.08.2009
9
Setting and controlling the dome camera
9.1
Camera adressing
Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7 Bit8
Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7 Bit8
1
On Off Off Off Off Off Off Off
51
On On Off Off On On Off Off
2
Off On Off Off Off Off Off Off
52
Off Off On Off On On Off Off
49
On Off Off Off On On Off Off
253
On Off On On On On On On
50
Off On Off Off On On Off Off
254
Off On On On On On On On
SW1 Adress
Bit Rate
bit1
bit2
19200 bps
Off
Off
2400 bps
On
Off
4800 bps
Off
On
9600 bps
On
On
SW2 Bit rate select
Example of camera addressing
Camera address = 1 x bit1 2 x bit2 4 x bit3 8 x bit4
16 x bit5 32 x bit6 64 x bit7
128 x bit8 status
*bit Status : On=1, Off=0
E.g. a200 = 1 x 0(Off) + 2 x 0(Off)+ 4 x 0(Off)+ 8 x 1(On)+
16 x 0(Off)+ 32 x 0(Off)+ 64 x 1(On)+ 128 x 1(On)
=8+64+128=200→Off/Off/Off/On/Off/Off/On/On