Start-Up
09.02
4-16
Siemens AG 6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit Operating Instructions
4.3.1.1.5
Selecting the source for control word 2 (bit 16-23)
Bit
16 17 18 19 20 21 22 23
Selection P. basic setting
578.1 579.1
583.1
Selection P. reserve setting
578.2 579.2
583.2
Value
Source
0000 Constant value = 0
xG/R xG/R
xG/R
0001 Constant value = 1
x x
x
1001 CUR, BE1, -X101:9
x x
x
1002 CUR, BE2, -X101:10
x x
x
1003 CUR, BE3, -X101:11
x x
x
1004 CUR, BE4, -X101:12
x x
x
1005 CUR, BE5, -X101:13
x x
x
1010 PMU
2001 SST1 (PMU -X300 or -X100:1...5)
Word1
2004 SST1 (PMU -X300 or -X100:1...5)
Word4
x x
x
OPTIONS
3001 CB/TB (Word1)
3004 CB/TB (Word4)
x x
x
4101 SCI 1 and 2, Slave 1, BE1
x x
x
4102 BE2
x x
x
...
Consecutively to
x x
x
4110 BE10
x x
x
4111 only SCI 2, Slave 1, BE11
x x
x
4112 BE12
x x
x
...
Consecutively to
x x
x
4116 BE16
x x
x
4201 SCI 1 and 2, Slave 2, BE1
x x
x
4202 BE2
x x
x
...
Consecutively to
x x
x
4210 BE10
x x
x
4211
only SCI 2, Slave 2, BE11
x x
x
4212 BE12
x x
x
...
Consecutively to
x x
x
4216 BE16
x x
x
4501 SCB-SST (USS /Peer-t-Peer) Word1
4504 SCB-SST (USS /Peer-t-Peer) Word4
x x
x
6001 SST2 (PTP1, A2-X117:1..5) Word 1
x x
x
...
Consecutively to
x x
x
6005 SST2 (PTP1, A2-X117:1..5) Word 5
x x
x
x: Value can be assigned for the selection parameters
Factory setting: xG:
for basic setting with P077=0
xR:
for reserve setting with P077=0