09.02
Parameter List
Siemens AG 6SE7087-6AK85-1AA0
5-35
Rectifier/Regenerating Unit Operating Instructions
PNU
*
: Conf.
Par.
OP1S parameter name
Description
Value range
[phys. unit]
Selection text
Display
Indices
Factory-
setting
See
Modify
(access /
status)
r730 SCB
Diagnostics
SCB diagnostics
All values in HEX display
If a quantity is represented, overflow takes place at FF Hex.
The meaning of several Indices depends of the selected SCB protocol
(P682).
i001: flTC
Number of error-free telegrams
i002: Terr
Number of error telegrams
i003: Ferr
Number of byte frame-errors
i004: Orun
Number of overrun errors
i005: Prty
Parity error
i006: STX
STX error
i007: ETX
ETX error
i008: BCC
Block check error
i009: L/KL
USS/Peer to Peer: incorrect telegram length
SCI modules: required maximum number of terminals
according to process data wiring (P554 to P631).
i010: T/An
USS: Timeout
SCI Modules: required analog inputs / outputs
according to process data wiring of the setpoint
channel and actual value output via SCI (P664) .
i011: BCd0
PCB code word 0
i012: BCd1
PCB code word 1
i013: Warn
SCB-DPR- warning word
i014: Sl1?
Information, if slave 1 needed and if yes, which type.
0: no slave needed
1: SCI1
2: SCI2
i015: Sl2?
Information, if slave 2 needed and if yes, which type.
0: no slave needed
1: SCI1
2: SCI2
i016: IniF:
with 'SCI modules': initialization fault
PNU=2DAHex; Type=L2; Scaling: 1Hex
=
∧
1
16
3/ HBR
r731 CB/TB
Diagnostics
For detailed information see manuals of the used communication boards
(CB) or technology boards (TB).
PNU=2DBHex; Type=L2; Scaling: 1Hex
=
∧
1
32
3/ HBR
r748 Fault
Time
The instants at which faults occur (reading of the hours counter r013 at the
instant the fault occurs)
See parameter r947 for details
Trip description by:
r947
Fault number
r949
Fault value
r951
List of fault texts
P952
Number of faults
PNU=2ECHex; Type=O2; Scaling: 1Hex
=
∧
1
24
2/ BR