The CBC does not respond to a parameter request job until the drive data are available. This normally
takes 20 ms. The response times will be longer only if change (write) jobs including storage of the value
in the EEPROM are received from other sources (e.g. serial basic converter interface), resulting in a
delay in job execution
In certain system states (e.g. initialization states), parameter processing is greatly delayed or does not
take place at all.
The master may not issue a new parameter request job until any current parameter job has been
acknowledged.
4.5.3.2 Diagnostic
tools:
LED displays on the CBC (flashing LEDs indicate normal operation):
Red LED
Status of CBC
Yellow LED
Communication between SIMOVERT and CBC
Green LED
Communication between CBC and CAN Bus
LED
red yellow
green
Status
flashing flashing flashing Normal
operation
flashing
off
on
CBC waiting for commencement of initialization by SIMOVERT
flashing
on
off
CBC waiting for end of initialization by SIMOVERT
flashing flashing
off No
PZD data exchange via CAN Bus
flashing on
on
CBC
defective
Diagnostic parameter r731:
Value
Meaning
r731.001 0
1
2
5
7
13
14
15
20
21
22
23
35
36
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
No fault
Fault F080/fault value 5 is displayed under fault conditions:
Fault values for CAN layer 2:
Incorrect address on CAN Bus (P918 / slave address)
Incorrect CAN identifier with PKW Request (P696)
Incorrect CAN identifier with PKW Request-Broadcast (P704)
Incorrect CAN identifier with PZD Receive (P697)
Incorrect CAN identifier with PZD Transmit (P698)
PZD transmit length = 0 (P699)
PZD transmit length > 16 , i.e. too long (P699)
Incorrect CAN identifier with PZD Receive-Broadcast (P701)
Incorrect CAN identifier with PZD Receive-Multicast (P702)
Incorrect CAN identifier with PZD Receive-Internode (P703)
Invalid baud rate (P705)
Incorrect CAN protocol type (P706)
PKW Request-Broadcast (P704) without PKW Request (P696)
Overlap between CAN identifier PKW and PKW Broadcast
Overlap between CAN identifier PKW and PZD Receive
Overlap between CAN identifier PKW and PZD Transmit
Overlap between CAN identifier PKW and PZD Receive-Broadcast
Overlap between CAN identifier PKW and PZD Receive-Multicast
Overlap between CAN identifier PKW and PZD Receive-Internode
Overlap between CAN identifier PKW Broadcast and PZD Receive
Overlap between CAN identifier PKW Broadcast and PZD Transmit
Overlap between CAN identifier PKW Broadcast and PZD Receive-Broadcast
Overlap between CAN identifier PKW Broadcast and PZD Receive-Multicast
Overlap between CAN identifier PKW Broadcast and PZD Receive-Internode
Overlap between CAN identifier PZD Receive and PZD Transmit
Overlap between CAN identifier PZD Receive and PZD Receive-Broadcast
Overlap between CAN identifier PZD Receive and PZD Receive-Multicast
Overlap between CAN identifier PZD Receive and PZD Receive-Internode
Overlap between CAN identifier PZD Transmit and PZD Receive-Broadcast
Overlap between CAN identifier PZD Transmit and PZD Receive-Multicast
Overlap between CAN identifier PZD Transmit and PZD Receive Internode
Overlap between CAN identifier PZD Receive-Broadcast and PZD Receive-Multicast
Overlap between CAN identifier PZD Receive-Broadcast and PZD Receive-Internode