Description of the motor
2.3 Technical features and ambient conditions
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
33
Risk to persons as a result of strong magnetic fields
WARNING
Risk of death as a result of permanent magnet fields
The permanent magnets in the motors represents a danger for people with active medical
implants, who come close to the motors. This is also the case when the motor is switched
off.
Examples of active medical implants include: Heart pacemakers, insulin pumps.
•
If you are affected, stay a minimum distance of 300 mm from the permanent magnets
(tripping threshold for static magnetic fields of 0.5 mT according to the Directive
2013/35/EU).
With regard to the effect of strong magnetic fields on people, in Germany the DGUV
regulation 103-013 "Electromagnetic fields" of the German Social Accident Insurance must
be complied with! This regulation lists all of the requirements that must be observed at
workplaces. In other countries, the relevant applicable national and local regulations and
requirements must be taken into account.
For magnetic fields, you must carefully comply with the requirements laid down in the DGUV
regulation 103-013 of the German Social Accident Insurance.
CAUTION
Safety distance to the rotor
The rotor magnetic fields are permanent. If you come into direct bodily contact with the
rotors, a static magnetic flux density of 2 T is not exceeded.
•
Carefully comply with the DGUV regulation 103-013, Paragraph 14 "Systems with high
static magnetic fields".
WARNING
Electrical shock hazard
Every movement of the rotor compared with the stator and vice versa induces a voltage at
the stator power connections.
If you use defective cable ports, you could suffer an electric shock.
•
Do not touch the cable ports.
•
Correctly connect the stator power connections, or insulate them properly.