Electrical connection
8.3 System integration
1FW6 High Speed built-in torque motors
258
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
NOTICE
Damage to cables
Cables subject to high acceleration rates can wear more quickly. The cables permanently
connected to the motor cannot be replaced if they are damaged.
•
Observe the permissible acceleration rates for the cables.
•
Do not use a drag chain for the cables permanently attached to the motor.
Also refer to Chapter "System integration". Data on the motor feeder cables, see Chapter
"Data of the power cable at the stator" and catalog.
MOTION-CONNECT cables from the terminal box provided by the customer or extensions
for the power and signal connection, see catalog.
Specification of the motor feeder cables
The built-in torque motors are supplied with MOTION-CONNECT cables according to the
catalog from which you can take the technical data:
Power cable: MOTION-CONNECT 800PLUS, type 6FX8 *)
Signal cable: MOTION-CONNECT 800PLUS, type 6FX8
*) Unlike what is stated in the catalog, the permissible operating temperature on the surface is -20 to +90 °C.