Technical data and characteristics
6.2 Data sheets and characteristics
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
159
Technical data
1FW6092
Symbol
Unit
-xxC15-6Axx -xxC15-8Fxx *)
Data for main motor cooler
Maximum dissipated thermal power
Q
H,MAX
kW
7.13
7.2
Recommended minimum volume flow rate
H,MIN
l/min
12.1
12.1
Coolant temperature rise
Δ
T
H
K
8.49
8.58
Pressure drop
Δ
p
H
bar
1.38
1.38
*) From a speed of 2400 rpm, a pulse frequency > 4 kHz is required to operate the motor. Observe an appropriate Motor