Configuration
5.4 Mounting
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
117
①
NDE flange with cable outlet
Figure 5-14 Restricted screw-on area on the NDE flange of the stator
①
DE flange
②
NDE flange
Figure 5-15 DE flange and NDE flange on the stator
You may only mount the rotors for transmitting the output load at the DE flange. The drilling
pattern on the NDE flange is only suitable for lower strength requirements (e.g. handling
purposes) due to weaker dimensioning. According to the diagrams below, 2 mounting
positions are possible. The active center of the stator must always be at the same height as
the active center of the rotor. You will find the dimensions for this on the following dimension
sheets.