Description of the motor
2.3 Technical features and ambient conditions
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
35
Note
Installation device
Because of the numerous installation situations and installation constraints, it is not possible
to specify a general joining fixture.
First aid in the case of accidents involving permanent magnets
●
Stay calm.
●
If the machine is energized, press the emergency stop switch and open the main switch if
necessary.
●
Administer FIRST AID. Call for further help if required.
●
To free jammed parts of the body (e.g. hands, fingers, feet), pull apart components that
are clamped together.
–
Do this using the non-magnetic hammer to drive the non-magnetic wedges into the
separating rift.
–
Release the jammed body parts.
●
If necessary, call the emergency medical service or an emergency physician.
Material damage caused by strong magnetic fields
NOTICE
Data loss caused by strong magnetic fields
If you are close to the rotor (< 100 mm) any magnetic or electronic data medium as well as
electronic devices that you are carrying can be destroyed. For example, credit cards, USB
sticks, floppy disks and watches are at risk.
•
Do not carry any magnetic/electronic data media and no electronic devices when you
are close to a rotor!