Mechanical properties
3.1 Cooling
1FW6 High Speed built-in torque motors
54
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
3.1.1
Cooling circuits
Cooling circuit requirements
Avoid algae growth by using suitable chemical agents and opaque water hoses.
We recommend that the cooling circuits be designed as closed systems. The maximum
permissible pressure is 10 bar.
NOTICE
Blocked and clogged cooling circuits
Cooling circuits can become blocked and clogged as a result of pollution and longer-term
deposits.
•
We recommend that you use a separate cooling circuit to cool the motors.
●
If you use the machine cooling circuits to also cool the motors, you must ensure that the
coolant fully complies with the requirements listed in this chapter.
●
Also note the maximum non-operational times of cooling circuits corresponding to the
coolant manufacturer’s data.
Materials used in the cooling circuits of torque motors
Table 3- 1
Materials in the cooling circuits of torque motors (not including the material used for the connections)
Cooling jacket for
1FW6092, 1FW6132 and
1FW6152
Integrated cooling
(main cooler) for
1FW6192 and 1FW6232
Integrated cooling
(precision cooler) for
1FW6192 and 1FW6232
Cooling connection adapter
for
1FW6192 and 1FW6232
•
AlMgSi1
(EN AW 6082 T6)
for 1FW6092
•
S355J2G3
(EN 10025)
for 1FW6132 and
1FW6152
•
Viton® (FPM) gasket
•
X6CrNiTi18-10
(EN 10088)
•
SF-Cu
(DIN 17671)
•
CW617N
(EN 12449 / EN 12167)
•
Viton® (FPM) gasket
•
Ag 102
(EN 1045) +
welding flux EN 1045-
FH10
•
X6CrNiTi18-10
(EN 10088)
•
SF-Cu
(DIN 17671)
•
CW617N
(EN 12449 / EN 12167)
•
Viton® (FPM) gasket
•
CW617N
(EN 12449 / EN 12167)
•
Viton® (FPM) gasket