25
8011703/XF49/V3-1/2019-09| SICK
O P E R A T I N G I N S T R U C T I O N S | VICOTEC320
Subject to change without notice
INSTALLATION
5
5.7.2
Connecting the sensors to the connection unit
1
Plug the connection lines that are mounted firmly on the connection unit in the
corresponding sockets of the sender/receiver unit.
2
Connect the connection line to the reflector with the connection unit:
a) Open the connection unit.
b) Unscrew M screw fitting for W3 (1).
c) Pull the connection line through the M screw fitting and connect to the W3
connection (2).
d) 35
e) Tighten the M screw fitting tight with a jaw wrench.
3
Plug the connection line into the reflector.
4
Fasten the connection lines to the tunnel wall.
Observe the wiring diagram on the rear of the cover.