23
8011703/XF49/V3-1/2019-09| SICK
O P E R A T I N G I N S T R U C T I O N S | VICOTEC320
Subject to change without notice
INSTALLATION
5
12
Repeat steps 5 to 11 on the opposite sensor and laser adjustment unit.
13
Unscrew and remove the laser adjustment unit.
5.6.3
Fitting the connection unit
Position the connection unit so that it can be connected to the sender/receiver unit with
the 1 m long cables.
1
Determine the installation location for the connection unit according to the project
planning.
2
Drill the openings according to the Drilling plan,
see Fig. “Connection unit assembly drill-
.
3
Insert dowels or wall ties according to the manufacturer's assembly specifications (walls
must be made of at least C20/25 to C25/30 concrete).
4
Screw the connection unit on.
Fig. 14: Connection unit assembly drilling plan
105
105
210
210
A
182
182
15
0
15
0
15
0
15
0
15
0
15 x 50
+2
0
15
0