Technical Information
Chapter
4
RFU63x
Electrical installation
8014335/YUO7/2016-04-04
©
SICK AG · Germany · All rights reserved · Subject to change without notice
75
4.9.12
Wiring the "Result 2" switching output in the CDM420-0006 connection module
RFU630
CDM420-0006
V
S
= DC 18 V ... 30 V
Load (e.g. PLC)
13
5
.
.
.
15
Result 2
16
GND
5
Shield
+24 V* (V
S
)
V
S
GND
V
out
Result 2
Result 2
GND
14
1
2
1
Quenching circuit:
Install anti-surge
diode directly at
the load!
For inductive load:
Adapter cable
1)2)
e.g. no. 2055419 (2 m)
6
1
10 5
11
15
Pin and wire color assignment of prefabricated cables
Ratings for “Result 2” switching output
PNP switching against the supply
voltage V
S
(+24 V*)
(default setting: no function,
logic: not inverted [active high])
– Short-circuit proof + temperature protected
– Galvanically not separate from V
S
(+24 V*)
0 V ≤ V
out
≤ V
S
(V
S
− 1.5 V) ≤ V
out
≤ V
S
with I
out
≤ 100 mA
Switching
behavior
Features
Electrical
values
M12
female
connector,
17-pin
2
14
1
Signal
V
S
Result 2
GND
Adapter cable
1)2)
Adapter cable
3)4)5)
Male
connector,
D-Sub HD,
15-pin
1
13
5
M12-
female
connector,
17-pin
2
14
1
Open
end
3)
,
17 cores
Blue
Brown-green
Brown
Open
end
4)
,
17 cores
Brown
Brown-green
Blue
Open
end
5)
,
17 cores
White
White-green
Gray
1) Adapter cable no. 2056184 (0.35 m), no. 2049764 (0.9 m), no. 2055419 (2 m),
no. 2055420 (3 m), no. 2055859 (5 m).
2) Adapter cable, suitable for drag chain use, no. 2061480 (2 m), no. 2061605 (3 m),
no. 2061481 (5 m).
3) Adapter cable no. 6042772 (3 m), no. 6042773 (5 m), no. 6048817 (10 m).
4) Adapter cable ECOLAB, suitable for drag chain use, no. 2070425 (3 m),
no. 2070426 (5 m), no. 2070427 (10 m).
5) Adapter cable, suitable for drag chain use no. 6045141 (5 m).
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
Female connector,
D-Sub-HD, 15-pin
Male connector, M12,
17-pin, A-coded