background image

CLEAR

Clears Preamble
and Postamble.
Resets scanned
parameter back to
default settings.

Preamble

Scan up to 15 characters
from the Full ASCII
Menu. Scan

SET

when

finished

Beep Options

* 0)  Ack.

1) Ack Only

RESET

WARNING!

Scanning RESET after scanning START

SETUP resets the reader back to DEFAULT settings,
eliminating any setup changes for all parameters.

MSI/Plessey

* 0) Disable

1) Enable 1 Mod 10
2) Enable 2 Mod 10
3) Enable Mod 11/Mod 10

* 4) Transmit no check digit

5) Transmit 1 check digit

6) Transmit 2 check digits

7)Enable Plessey bar code

Code 128

0) Disable Code 128

* 1) Enable Code 128

2) Disable UCC/EAN 128

* 3) Enable UCC/EAN 128

Codabar

0) Enable Codabar

* 1) Disable Codabar

2) Enable CLSI Codabar

* 3) Disable CLSI Codabar
* 4) Suppress Start/Stop

5) Enable Start Stop

UPC and EAN

* 0) Enable UPC/EAN
1) Disable UPC/EAN
2) Enable Supplements

*

3) Disable Supplements

* 4) Transmit UPC-A NSC

5) Don’t Transmit UPC-A NSC

* 6) Transmit UPC-A Check Digit

7) Don’t Transmit UPC-A Check Digit
8) Transmit UPC-E NSC and EAN-8 Flag Ch

* 9) Don’t Transmit UPC-E NSC or EAN-8 Flag Ch

A) Transmit UPC-E/EAN-8 Check Digit

* B) Don’t Transmit UPC-E/EAN-8 Check Digit
* C) UPC-E Compressed Transmission

D) UPC-E Expanded Transmission

* E) EAN-8 observes 9 & A above

F) EAN is forced to transmit 8 digits always

Code 93

0) Enable

* 1) Disable

2) Enable Full ASCII

* 3) Disable Full ASCII

2 of 5 Code

0) Enable I 2of5

* 1) Disable I 2of5

2) Enable Check Digit

* 3) Disable Chk Digit

4)Transmit Check Digit

* 5) Don’t Transmit Ck

6) Enable 2 of 5

* 7) Disable 2 of 5

Code 3 of 9

* 0) Enable Code 39

1) Disable Code 39

* 2) Enable Full ASCII

3) Disable Full ASCII

* 4) Enable Accumulate Mode

5) Disable Accumulate Mode
6) Transmit Start/Stop

* 7) Don’t Transmit Start/Stop

8) Enable Mod 43 Check Character

* 9) Disable Mod 43 Check Character

A) Transmit Mod 43 Check Character

* B) Don’t Transmit Mod 43 Check Character

C) Caps Lock ON

* D) Caps Lock OFF

Barpad Table

LZ360-RF & LZ404-RF Laser Setup Menu

Start Setup

End Setup

1) scan “

Start Setup

” to put RF Laser into setup mode .

2) scan

parameter

to change, (i.e. Code 3 of 9, Postamble ).

3) scan corresponding bar codes from

Barpad Table

(0-9,A-F) to change settings.

4) scan “

End Setup

” after all changes have been made.

Instant Setup options in

RED

section do not require scanning

Start Setup

*/A/*

*/B/*

*0*

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

*/+/*

*/-/*

*/C/*

*/D/*

*/1/*

*/5/*

*/S/*

*/R/*

*1*
*2*
*3*
*4*
*5*
*6*
*7*

*/2/*

*8*
*9*

*A*
*B*
*C*

*D*
*E*

*F*

*///*

*/W/*

*/./*

*/L/*

* default setting 04/12

*/$/*

2 of 5 Length

Scan 2 digit length
(default is 06)

Postamble

Scan up to 15 characters
from the Full ASCII
Menu.Scan

SET

when

finished.

GS1-14

* 0) Disable

1) Standard 14 digits
2) 14 + Identifiers
3) 14 + UCC-128 Emul.

*/%/*

SET

Aiming Dot Duration (LZ404RF ONLY)

Scan 1 digit from the
Barpad Menu, from 0
to 9 seconds

*/K/*

Laser Status

(Instant Setting)

*/$A/*

Transmit Setup

(Instant Setting)

*/$C/*

Link Test Code

(Instant Setting)

Test RF Transmission
without
tramsmitting data.

*--*

Characters

Redefines
output for
characters

*.1.*

*/$B/*

*/$F/*

Pair Laser to Base

(Instant Setting)

Range Test

(Instant Setting)

Terminator Character

* 0) CR (Enter)

1) Tab
2) None

*/H/*

Reviews: