Chapter
4
Technical Information
RFU63x RFID Write/Read Device (UHF)
28
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8014335/YUO7/2016-04-04
Electrical installation
4.2
Overview of all interfaces and connection options
4.2.1
RFU630-131xx with integrated antenna
Configuration and diagnostics
Reading mode
e.g. cable no. 2055419 (2 m)
e.g. cable no. 6049780 (2 m)
CDB650-204
Serial
Serial
Serial
Serial
e.g. cable
no. 6034414 (2 m)
e.g. cable
no. 6036106 (2 m)
Configuration
Diagnostics
SOPAS
SOPAS
“Power/Serial Data/CAN/I/O”
(AUX 1, HOST 1)
No. 1064114
...
...
1 2
DC 18 V ... 30 V
GND
PC
e.g. cable no. 2014054 (2 m)
“Serial RS-232” (AUX 1), alternatively to Ethernet AUX port
“Ethernet” (AUX 2)
DC 18 V ... 30 V
1)
“USB” (AUX 3),
alternatively to Ethernet AUX port
External antennae (optional)
2)
...
1
3
2) e.g. RFA630-000 for region Europe
1) Required minimum input voltage depends on the cable
length between CDB650-204 and RFU630-131xx,
see RFU63x-131xx operating instructions (no. 8016526)
Ethernet
Ethernet
USB
USB
RFU630-
131xx
“Ethernet” (HOST 2)
Input 2
(e.g. encoder)
Input 1
(e.g. external reading trigger)
Output 1
(e.g. indicator lamp)
Output 2
RFU630-
131xx
e.g. cable no. 2055419 (2 m)
e.g. cable no. 6049780 (2 m)
“Serial RS-232/RS-422/485” (HOST 1), alternatively to Ethernet HOST port
CDB650-204
Serial
Serial
e.g. cable
no. 6034414 (2 m)
“Power/Serial Data/CAN/I/O”
(AUX 1, HOST 1)
No. 1064114
...
...
1 2
DC 18 V ... 30 V
GND
HOST
Further data
processing
DC 18 V ... 30 V
1)
Inputs/Outputs = digital
Additional external inputs/outputs via
parameter cloning module CMC600
External antennae (optional)
2)
...
1
3
Reading result
2) e.g. RFA630-000 for region Europe
1) Required minimum input voltage depends on the cable
length between CDB650-204 and RFU630-131xx,
see RFU63x-131xx operating instructions (no. 8016526)
Ethernet
Ethernet