Chapter
4
Technical Information
RFU63x RFID Write/Read Device (UHF)
72
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8014335/YUO7/2016-04-04
Electrical installation
4.9.9
Wiring the "External input 1" switching input in the CDM420-0006 connection
module
+24 V* = DC 18 V ... 30 V
V
in
= max. 30 V
CDM420-0006
CDM420-0006
PNP sensor
V
S
GND
Out
GND
S6
e.g. photo-electric
switch
V
S ext
RFU630
CDM420-0006
PNP sensor
V
S
GND
3.32 K
6.64 K
V
in
V
in
V
in
Out
GND
S6
e.g. photo-electric switch
CMC600
GND
S6
CMC600
CMC600
a) Sensor supplied by CDM420-0006
b) Sensor connected electrically isolated and externally supplied
d) Switch connected electrically isolated and externally supplied
c) Switch supplied by CDM420-0006
Connect the switch as shown in b)
Serial Aux
(RS-232)
ON
OFF
S6 : SGND
No
YES
S8 : CMC
ON
OFF
S6 : SGND
No
YES
S8 : CMC
No
YES
S8 : CMC
ON
OFF
S6 : SGND
17 SGND
8 Shield
39 +24 V*
18 Aux In 1
17 SGND
8 Shield
39 +24 V*
18 Aux In 1
17 SGND
8 Shield
39 +24 V*
18 Aux In 1
+24V*
+24V*
+24V*
“External
input 1”
SensGND
SensGND
SensGND
Software-controlled, the CMC600 transfers the
switching status of its physical “Aux In 1” input
automatically via the cable to the serial Aux data
interface of the RFU630.
The RFU630 converts the status internally to its
logical “External input 1“.
Ratings for “External input 1”
("Aux In 1“ switching input)
Switch S6: SGND-GND
ON:
GND of the sensor connected to GND
of
CDM420-0006/CMC600.
OFF:
GND of the sensor connected to SensGND of
CDM420-0006/RFU630 (electrically isolated
to the CDM420-0006/RFU630).
Selected reference potential valid for all switching
inputs ( “Sensor 1/2” and “Aux In 1/2” )
Function assignment to "External input 1" via SOPAS:
- Start of reading clock
- Stop of reading clock
- if required further functions in the future
Power fed to the input starts the
assigned function, e.g. start of reading
clock.
(default setting: logic not inverted
[active high], debouncing 10 ms)
– Optodecoupled, reverse polarity
protected
– Can be wired with the PNP output of
a sensor
– SensGND is the shared isolated
ground of all switching inputs
Low: V
in
≤ 2 V; I
in
≤ 0.3 mA
High: 6 V ≤ V
in
≤ 30 V;
0.7 mA ≤ I
in
≤ 5 mA
Switching
behavior
Features
Electrical
values