Chapter
8
Operating Instructions
Compact OMNI Scanner
8-14
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 237/0000/07-05-2002
Troubleshooting
8.5.4
Malfunctions in Reading mode: errors in the result status output
¾
Check whether the "Device Ready" LED lights up.
If the LED does not light, see
.
8.6
SICK Support
If a system error occurs repeatedly
( "CLVSYS-Failure: xxx", xxx= 000 ... 299)
or if you can-
not correct an error using the above measures, the CLX may be defective. The CLX does
not contain any components that can be repaired by the user.
Please contact your local SICK office or subsidiary. The telephone and fax numbers are list-
ed on the
back page
of this manual.
¾
Please contact SICK before sending the device for repair.
Malfunction
Possible cause
Remedy
The
– "Result 1"
(default setting: Device Ready)
– "Result 2"
(default setting: Good Read)
– "Result 3"
(default setting: No Read)
– "Result 4"
(default setting: Match 1)
switching outputs are not outputting any
pulses
•
The event associated with the assigned
function for outputting the result status of
the read does not occur in the reading
operation.
•
Incorrect switching mode parameterized
in the CLX.
•
Not applicable.
•
In the "CLV-Setup" program: choose the
D
EVICE
C
ONFIGURATION
tab. Click the E
DIT
R
ESULT
O
UTPUTS
button. Are the outputs
set to N
O
I
NVERT
O
UTPUT
? Change if ne-
cessary. Download to CLX!
Table 8-8: Troubleshooting: errors in the result status output in Reading mode