Troubleshooting
6. "error: writing parameters
CLV->EXT internal para-
meters loaded"
(Error type: 110, 111,
112)
Start option: S
TART
WITH
C
OPY
I
NTERN
–> E
XTERN
.
The CLX was
not
able to copy
the internal parameter set to
the external memory. It has
loaded the internal parameter
set to its RAM
Data transmission error.
Check whether the external para-
meter memory is connected cor-
rectly (free wiring: check wire
assignment).
Repeat the startup procedure. If
the error is still present, contact
the SICK Service department.
7. "warning: additional
unknown parameter(s)
external parameters
loaded"
(Error type: 101, 114)
Start option: S
TART
WITH
E
XTERNAL
P
ARAMETERS
.
The CLX has successfully
loaded the external parameter
set with tolerated errors
1)
to its
RAM.
Transfer ok but different parame-
ter versions in the external
memory and the CLX.
Upload the parameter set to CLV-
Setup and check the values
1)
.
1) see footnote 1) in
Message
Meaning
Possible cause
Remedy
Table 8-3: For messages for problems accessing the external parameter memory