Operating Instructions
Chapter
5
CLX 490
8 009 237/0000/07-05-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-5
Electrical installation
Connecting the CLX with external parameter memory
a) CLX without heater:
Connection Modules: AMV/S 60, AMV 30-071, BMV 10
¾
Cover the connections on the CLX with the connector cover (parameter memory),
no. 2 020 307. Connect the plug/socket on the cables ("Host/Term" and " I/O"
connections) with the appropriate connections on the AMV/S or BMV 10.
Connection Module: BMS 20
¾
Cover the connections on the CLX with the connector cover (parameter memory)
no. 2 020 308. Connect the 9-pin plug ("Host/Term" connection) to the socket on the
BMS 20. Connect the wires of the free cable end ( "I/O" terminal) to the terminal strips
in the BMS 20.
Recommendation
Use the external parameter memory no. 2 020 981 (open cable ends) for connecting the
device to non-SICK Power packs/wiring configurations.
b) CLX with heater:
Connection Module: AMV 100/200
¾
AMV 100: Cover the connections on the CLX with the connector cover (parameter
memory), no. 2 021 689, labeled ”SCANNER”. Connect the other connector covers, la-
beled "HOST", to the corresponding connections on the AMV 100.
¾
AMV 200: see AMV 100,
proceed in the same way with the second CLX.
5.2.6
Connections/cables for the IP 65 connector cover
(connection to AMV 100/200 or BMV 10)
The connector cover (optional accessory) with 15-pin D Sub HD plug connections is used
to cover the terminals on the CLX so that the enclosure rating IP 65 is provided.
The connector cover is prefabricated with two cables, each of 3 m in length, and is available
with two different cable ends:
•
with one additional connector cover at the other end (pins assignment identical to that
of the CLX terminals), no. 2 021 298
•
with two open cable ends, no. 2 021 267
CLX with heater:
Both connector cover variants can be used with temperatures up to max. –50
°
C if the CLX
is stationary and the cables are not moved. If the cables are moved due to changes in the
position of the CLX, the temperature must not drop below max. –40
°
C.
Recommendation
Use the external parameter memory no. 2 020 267 (open cable ends) for connecting the
device to non-SICK Power packs/wiring configurations.