Chapter
10
Operating Instructions
Compact OMNI Scanner
10-10
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 237/0000/07-05-2002
Appendix
Start with copy internal -> external
When it starts, the CLX loads the internal parameter set to its RAM. It then copies the
parameter set to the external memory and resets the start option to S
TART
WITH
E
XTERNAL
P
ARAMETERS
.
The two "Device Ready" and "Read Result" LEDs blink alternately for approx. 10s. The
"Device Ready" LED then lights up constantly.
The data is not lost when the device is switched off since it is stored permanently in the CLX
and is identical to the internal parameter set.
10.3.4
Switching on the device for the first time
Since the external parameter memory is empty on delivery, the "Device Ready" and "Read
Result" LEDs blink constantly when the device is switched on for the first time with the de-
fault setting (S
TART
WITH
E
XTERNAL
P
ARAMETER
). The CLX has not found an external
parameter set and has loaded the internal parameter set. However, it is not ready for
operation and does not output data on the host interface.
¾
Transfer the CLX parameter set to the parameter memory for the first time as described
Chapter 6.3.2 Switching the CLX with external parameter memory connected on for
the first time with the factory default settings, Page 6-4
10.3.5
Adjusting the parameter set in the external parameter memory after it has
been downloaded to the CLX
If the CLX is started with he S
TART
WITH
E
XTERNAL
P
ARAMETERS
option with an external param-
eter memory and if the parameter set is downloaded from CLV-Setup to the CLX with the
permanent
storage option, CLV-Setup asks you whether the new parameter set is also to
be copied to the external parameter memory (
This function prevents the CLX
from reloading the old parameter set the next time it starts.
¾
Adjust the parameter set in the external parameter memory as described in
Chapter 6.4.1 Configuring the CLX via the user interface of CLV-Setup, Page 6-5
Fig. 10-9:
CLV-Setup: dialog box for adjusting the external parameter memory