Chapter
5
Operating Instructions
Compact OMNI Scanner
5-8
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 237/0000/07-05-2002
Electrical installation
5.4
Preparations for electrical installation
5.4.1
Requirements for the host interface
The host interface of the CLX can be operated as an RS 422/485 or an RS 232 interface.
shows the recommended maximum cable lengths as a function of the selected
data transfer rate.
¾
To prevent interference, do not lay the cables parallel with power supply and motor ca-
bles over long distances, e. g. in cable ducts.
5.4.2
Supply voltage
The CLX requires a supply voltage of 18 ... 30 V DC for operation without a heater and
24 V DC +20%/–10% for operation with a heater, to IEC 742 (functional extra-low volt-
age). The power consumption of the individual types is as follows:
Table 5-8: Power consumption of the CLX
Power-up delay
The selected device number (default: 1) affects the power-up delay of the device. This is
useful if a large number of CLX (e. g. in the SICK network) are to be supplied from one power
source.
contains a list of the available intervals.
Tip
The device number can be selected on the D
EVICE
C
ONFIGURATION
tab in the "CLV-Setup"
program.
Interface type
Transfer rate
Distance from host
RS 232
up to 19 200 bit/s
38 400...57 600 bit/s
max. 10 m
max. 3 m
RS 422/485
1)
max. 38 400 bit/s
max. 57 600 bit/s
max. 1 200 m
max. 500 m
1) with suitable line termination
Table 5-7: Maximum cable lengths between the CLX and host
Type
Voltage
Heater
Power consumption
1)
Connection Modules
CLX 490-0010 18 ... 30 V DC
no
9 W (typ.)/ max. 16 W
AMV/S 60 or
AMV 30-071 or
BMV/BMH 10 or
BMS 20
CLX 490-0011 24 V DC
+20%/–10%
yes
75 W (typ.)/ max. 90 W
AMV 100/200
1) Switching outputs not connected
Device number GN
Power-up delay
Device number GN
Power-up delay
1; 11; 21; 31
0 ms
6; 16; 26
2 000 ms
2; 12; 22
400 ms
7; 17; 27
2 400 ms
3; 13; 23
800 ms
8; 18; 28
2 800 ms
4; 14; 24
1 200 ms
9; 19; 29
3 200 ms
5; 15; 25
1 600 ms
10; 20; 30
3 600 ms
Table 5-9: Power-up delay as a function of the device number GN