Define monitoring cases
This dialog box appears. This is where you define the monitoring
cases to be used.
One monitoring case is defined already when the system is
shipped, although you can change its settings as you wish.
To change the monitoring case:
•
Click on Edit and change the settings as you need them.
To define other monitoring cases:
•
Click on Add.
•
Enter a name for the monitoring case and click on
Continue.
This dialog box appears.
•
Select the sensor to be active in this monitoring case.
•
Select the monitoring area you want monitored on the
selected sensor.
•
Click on Continue.
This dialog box appears.
•
For the available inputs, define the input information on
which the monitoring case is to be activated:
X = low or high
0 = low
1 = high
Note:
Each input comprises two signals, which must always be inverse
to each other, e.g. for input A signals A
1
and A
2
:
Input A low:
A
1
= 1 and A
2
= 0
Input A high:
A
1
= 0 and A
2
= 1
In this, the value set in the dialog box always corresponds to the
signal level of the assigned input A
2
or B
2
, C
2
, D
2
. (For cabling of
inputs see section 8.2).
•
Click on Continue.