Operating instructions Distance sensors Dx35
IO-Link interface
46
© SICK AG • Subject to change without notice • 8014868/YEF7/2014-09-02
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
107 (0x6B)
Process data
normalization
UINT16
R/W
•
0
… 50000 mm
Move process data
zero point in 1 mm
steps.
Table 16: SICK-specific service data – process data
9.3.6
SICK-specific – other settings
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
81 (0x51)
Multifunctional
input MF function
UINT8
R/W
•
0: Teach
• 1: Laser on/off
• 2: MF OFF
(MF deactivated)
1
99 (0x63)
Multifunctional
input MF level
(bit 0)
Multifunctional
input MF teach
confirmation on
Q1 (bit 1)
Record
R/W
Bit 0:
• 0: Low active
•
1: High active
Bit 1:
•
0: Inactive
• 1: Active
→
See Page 48,
Chapter 10.1
and Page 49,
Chapter 10.2.
104 (0x68)
Alarm function
(bit 0)
UINT8
R/W
•
0: Clamp
(zero-value output)
• 1: Hold
Select behavior for
the sensor if no
measurement is
possible.
• Clamp: The sensor
outputs "0".
• Hold: The last valid
measurement value
is retained.
Note
Do not set "hold"
option for ObSB mode.
→
See Page 49,
Chapter 10.2.
82 (0x52)
Pushbutton lock
UINT8
R/W
•
0: Switch OFF
• 1: Switch ON
0
68 (0x44)
Laser on/off
UINT8
R/W
• 0: Switch OFF
•
1: Switch ON
1
–
Table 17: SICK-specific service data – other settings