8014868/YEF7/2014-09-02 • © SICK AG • Subject to change without notice 45
Operating instructions Distance sensors Dx35
IO-Link interface
9.3.4
SICK-specific – teach
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
130 (0x82)
TEACH
UNIT16
W
• 0: Q1 DtO
(Q1 distance to
object)
• 1: Q2 DtO
(Q2 distance to
object)
• 2: Q1 near
• 3: Q1 far
• 4: Q1 centering
• 5: Q2 near
• 6: Q2 far
• 7: Q2 centering
• 8: Q1 ObSB
(Q1 object between
sensor and
background)
• 9: Q2 ObSB
(Q2 object between
sensor and
background)
• 10: Q2 4 mA
• 11: Q2 20 mA
• 12: Q2 0 V
• 13: Q2 10 V
• 14: Q2 Analog
centering
• 15: Fine teach
+10 mm
• 16: Fine teach
-10 mm
A teach overwrites
a function that has
already been set
with a newly selected
function. For values
that are not taught
in again and for an
unsuccessful teach,
the old value is
retained.
1) SICK-specific service data – teach
9.3.5
SICK-specific – process data
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
83 (0x53)
Process data
structure
UINT8
R/W
• 0: DQ1+Q2
• 1: DVMA
+alarm
• 2:Level+VMA+alarm
•
3: Distance
• 4: D
signal quality
3
→
Page 39,
Chapter 9.2.
105 (0x69)
Process data
resolution
UINT8
R/W
• 0: 0.1 mm
•
1: 1 mm
• 2: 10 mm
Resolution distance
measurement value
for the process data
(IO-Link only)