Operating instructions Distance sensors Dx35
Commissioning
36
© SICK AG • Subject to change without notice • 8014868/YEF7/2014-09-02
8.5
Expert mode
Use expert mode to set the following functions:
• Function for multifunctional input MF:
External teach (factory setting), laser off, multifunctional input MF inac
-
tive
• Level for multifunctional input MF:
High active (factory setting), Low active
• For DT35/DL35 distance sensors:
Output behavior for output Q2:
4 … 20 mA (factory setting), 0 … 10 V, switching output Q2
Description
Active LED
LED slow … fast
Function for
multifunctional
input MF
Q1 near
• LED
slow … fast
flashes 1 x:
external teach
• LED
slow … fast
flashes 2 x:
laser off
• LED
slow … fast
flashes 3 x:
multifunctional input MF inactive
Level for
multifunctional
input MF
Q1 far
• LED
slow … fast
flashes 1 x:
low active
• LED
slow … fast
flashes 2 x:
high active
Output behavior
for Q2 output
1)
Q2 near
• LED
slow … fast
flashes 1 x: 4 ...
20 mA
• LED
slow … fast
flashes 2 x: 0 …
10 V
• LED
slow … fast
flashes 3 x: Switch
-
ing output
1) For DT35/DL35 distance sensors only
Table 8:
Overview of expert mode
Output: The Q2 output is to be set to 0 … 10 V.
1. From operating mode only: Press and hold
select
and
set
pushbuttons
simultaneously for longer than 10 seconds. The
Q1
near
LED lights up
and the LED
slow
…
fast
flashes cyclically according to the previous
setting.
2. Press repeatedly the pushbutton until the LED
Q2 near
lights up.
3. Press repeatedly the
set
pushbutton until the desired option has been
set.
• LED
slow … fast
flashes 1 x: 4 … 20 mA
• LED
slow … fast
flashes 2 x: 0 … 10 V
• LED
slow … fast
flashes 3 x: switching output.
4.
To leave expert mode, press and hold the
select
and
set
pushbuttons
simultaneously for longer than 10 seconds or wait 5 minutes without