8014868/YEF7/2014-09-02 • © SICK AG • Subject to change without notice 55
Operating instructions Distance sensors Dx35
Technical data
3)
DT35-Bxxxxx, DS35-Bxxxxx: At 6 % … 90 % remission
DL35-Bxxxxx, DR35-Bxxxxx: on "diamond grade" reflective tape
4)
Depends on the configured speed "super-slow" … "super-fast"
5) Continuous change of the distance from the object in the measuring range
6) Lateral entry of the object into the measuring range
Table 21: Performance data
Output rate, response time, and switching frequency as a function of the speed setting
All Dx35 except for DT35-B15551 and DS35-B15521
Super-fast
Fast
Medium
Slow
Super-slow
Output rate
1 ms
2 ms
4 ms
8 ms
32 ms
Response time
2.5 ms
6.5 ms
12.5 ms
24.5 ms
96.5 ms
Switching
frequency
333 Hz
100 Hz
50 Hz
25 Hz
6 Hz
DT35-B15551 and DS35-B15521
Super-fast
Fast
Medium
Slow
Super-slow
Output rate
2 ms
4 ms
8 ms
16 ms
64 ms
Response time
4.5 ms
12.5 ms
24.5 ms
48.5 ms
192.5 ms
Switching
frequency
166 Hz
50 Hz
25 Hz
12 Hz
3 Hz
Table 22: Overview of output rate, response time, and switching frequency
13.4
Power supply
Supply voltage V
S
1)
• 12 V DC … 30 V DC
• 18 V DC … 30 V DC (when using IO-Link)
•
DT35-Bxxxxx, DL-Bxxxxx: 13 V DC ... 30 V DC
(when using the analog voltage output)
Power consumption
2)
≤ 1.7 W
Residual ripple
3)
< 5 V
SS
1)
Limit values, reverse-polarity protected operation in short-circuit protected network: max. 8 A
2)
At 20 °C and without load
3) May not fall short of or exceed V
S
tolerances
Table 23: Power supply
13.5
Inputs
Multifunctional input (MF)
1)
1 x
→
See Page 36, Chapter 8.5
1)
Response time: ≤ 60 ms
Table 24:
Inputs