8014868/YEF7/2014-09-02 • © SICK AG • Subject to change without notice 43
Operating instructions Distance sensors Dx35
IO-Link interface
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
97 (0x61)
Timer function for
switching out-
put(s)
UINT8
R/W
•
0: Disabled
(deactivated)
• 1: ON delay
• 2: OFF delay
• 3: ON/OFF delay
• 4: One-shot
98 (0x62)
Time for timer
function
UINT8
R/W
0 … 255 ms
In 1 ms steps
Table 15: SICK-specific service data – outputs
9.3.3
SICK-specific – sensor performance
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
103 (0x67)
Response time
UINT8
R/W
• 0: Expert
• 1: Super-slow
•
2: Slow
• 3: Medium
• 4: Fast
• 5: Super-fast
2
Indexes 64, 67, and
66 available only if "0:
Expert" was selected
here.
64 (0x40)
Integration time of
the measurement
or output rate
UINT8
R/W
• 0
• 1
• 2
•
3
• 4
• 5
• 6
• 7
• 8
DT35 and DS35 red
laser, class 1 devices:
Integration time of
the measurement or
output rate 2
n
* 2 ms,
All other devices:
Integration time of
the measurement or
output rate 2
n
* 1 ms
Writable only if
"0: Expert" was
selected for index
"103".
67 (0x43)
Averaging
UINT8
R/W
• 1: OFF
•
2: Filter depth 2
• 4: Filter depth 4
• 8: Filter depth 8
• 16: Filter depth 16
Sliding averaging
over x measurement
values. Affects only
process data and
analog output, not the
switching behavior.
Writable only if
"0: Expert" was
selected for index
"103".