Operating instructions Distance sensors Dx35
IO-Link interface
44
© SICK AG • Subject to change without notice • 8014868/YEF7/2014-09-02
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
66 (0x42)
Bit filter for switch
-
ing output(s)
UINT8
R/W
• 0: OFF
•
2: Filter depth 2
• 4: Filter depth 4
• 8: Filter depth 8
• 16: Filter depth 16
Filter depth 4:
Four consecutive
measurement
values must
exceed or fall
below the
configured
switching point
in order for the
switching output
to react.
Defines how often the
switching requirement
(e.g. exceed switching
point Q1 far) has
to be fulfilled in
succession before
the switching output
changes its status.
The bit filter affects
only the switching
output behavior, not
the process data and
analog output.
Writable only if
"0: Expert" was
selected for index
"103".
1) SICK-specific service data – sensor performance