freely with most distance sensors and is stated in mm. More precise switching is
achieved by setting a lower value. Set a higher value for the hysteresis to ensure more
stable switching or reduce the probability of a faulty switch.
>
Measurement
>
>
Application settings
>
>
Edge height change
>
>
Hysteresis
>
Parameter
Factory setting
0 mm ... +100 mm
0.5 mm
Change direction
The
change direction
value defines whether changes in measured values which result in
smaller or larger distances are detected in both directions.
•
both: All changes in measured values within the set limits are detected.
•
Positive: Only changes in measured values within the set limits which result in
larger distances are detected (description applies to factory setting).
•
Negative: Only changes in measured values within the set limits which result in
smaller distances are detected (description applies to factory setting).
>
Measurement
>
>
Application settings
>
>
Edge height change
>
>
Change direction
>
Parameter
Factory setting
Both, positive, negative
Both
Cycle offset
The
cycle offset
value specifies which previous output value is compared with the value
currently measured.
NOTE
We recommend using the edge height change operating mode with a fixed cycle time,
. This ensures time consistency for the output of measured
values. In the
Auto
operating mode, fluctuating remission values of the object surface
can change the cycle time of the device, which means that reliable detection cannot be
guaranteed in the case of high detection speeds or small structures.
>
Measurement
>
>
Application settings
>
>
Edge height change
>
>
Cycle offset
>
Parameter
Factory setting
1 ... 256
8
8
OPERATION VIA DISPLAY
32
O P E R A T I N G I N S T R U C T I O N S | OD1000
8019642/18JN/2020-07-01 | SICK