Parameter
Factory setting
Qa teach-in:
Distance (0 V)
Distance (10 V)
-
-
Manual Qa teach-in:
Distance (0 V): -1,000.0 mm ... +1,000.0 mm
Distance (10 V): -1,000.0 mm ... +1,000.0 mm
-400.0 mm
+400.0 mm
8.4.2.4
Digital output
The Q2 digital output provides the following switching modes:
•
DtO, distance to object (1-point), one switching point
•
Window, two switching points
•
ObSB, object between sensor (device) and background, one switching point
•
Q2 = Q1 not
•
Alarm (only in
Advanced
user level)
•
Signal level warning (only in
Advanced
user level)
•
Edge height change (only in
Advanced
user level)
>
I/O interface
>
>
Q2/Qa output
>
>
Digital output
>
Parameter
Factory setting
Distance to object > Q2 teach-in:
Q2, Q2 not
-
Distance to object > manual Q2 teach-in:
-1,000.0 mm ... +1,000.0 mm
+400.0 mm
Distance to object > Q2 active status:
High, Low
High
Distance to object > Q2 hysteresis:
0000.0 mm ... +0100.0 mm
+1.0 mm
Distance to object > delay mode:
Off, switch-on delay, switch-off delay, switch-on/switch-off delay, 1
shot
Off
Distance to object > time for delay mode:
0000 ms ... 9,999 ms
100 ms
Window > Q2 teach-in:
Switching point 1, switching point 2
-
Window > manual Q2 teach-in:
Switching point 1, switching point 2
-
Window > Q2 active status:
High, Low
High
Window > Q2 hysteresis:
0000.0 mm ... +0100.0 mm
+1.0 mm
Window > delay mode:
Off, switch-on delay, switch-off delay, switch-on/switch-off delay, 1
shot
Off
Window > time for delay mode:
0000 ms ... 9,999 ms
100 ms
OPERATION VIA DISPLAY
8
8019642/18JN/2020-07-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD1000
47
Subject to change without notice