5
Teach-in request retains the last active Q
1
status in order, for example, to avoid toggling if
hysteresis is too low.
6
Teach-in execution time, max. 1 s
7
First signal edge at Q
1
after starting the teach-in: Initiate confirmation by inverting for
100 ms.
8
Result: OK (100 ms), error (300 ms)
9
Quit confirmation after 500 ms.
ß
Return to current digital output. The digital output can be modified via a new teach-in
point.
à
Teach-in failed
á
Error
>
I/O interface
>
>
In1 input
>
>
Teach confirmation
>
Parameter
Factory setting
Yes, no
No
8.5
Device
8.5.1
User level
Simple
and
Advanced
user levels are available.
Only certain functions are available depending on the user level set:
•
Easy: frequently required functions (factory setting)
•
Advanced: virtually all available functions
Changing the user level only affects operation via the display and via SOPAS ET. All
functions are available at all times for operation and configuration via IO-Link.
>
Device
>
>
User level
>
Parameter
Factory setting
Easy, Advanced
Easy
8.5.2
Reset
The device can be reset to the
factory settings
or to saved
customer settings
).
NOTE
Upon confirmation that the device is to be reset, it carries out a warm start. During the
device restarting process, the device and its function are temporarily deactivated.
>
Device
>
>
Reset
>
>
Factory settings
>
OPERATION VIA DISPLAY
8
8019642/18JN/2020-07-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD1000
53
Subject to change without notice