Multifunctional input (In1
input)
1 x
2)
IO-Link
Function: Process data, configuration, diagnostics, data storage
Data transmission rate: 230.4 kBit/s (COM3) / 38.4 kBit/s
(COM2)
Protocol: V 1.1 / V 1.0
1)
PNP: HIGH = U
V
- (< 3 V) / LOW = < 3 V; NPN: HIGH = < 3 V / LOW = U
V
.
2)
Can be used as laser off, external teach-in, or deactivated.
13.4
Ambient data
Table 12: Ambient data
Ambient operating temperature
–10 °C … +50 °C
1)
Storage temperature
–20 °C … +60 °C
Temperature drift
0.15 mm/K
Typ. ambient light immunity
Artificial light: ≤ 3,000 lx
2)
Sunlight: ≤ 10,000 lx
Vibration resistance
EN 60068-2-6 / EN 60068-2-64
Shock resistance
EN 60068-2-27
1)
At U
V
= 24 V.
2)
With constant object movement in the measuring range.
TECHNICAL DATA
13
8019642/18JN/2020-07-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD1000
67