136
‐
15. ENVIRONMENT CORRECTION
Generating sets may be loaded up to their rated power only under the
rated ambient conditions. If generating set use is under conditions
which do not conform to the reference conditions as stipulated in this
part of ISO 8528, and if cooling of the engine or alternator is impaired,
e.g., as a result of operation in restricted areas, a reduction in power
is necessary.
The rated power output is based on the standard condition as follows:
Altitude
:
0m
Ambient temperature: 25
℃
Relative humidity: 30%
Factor of environment correction C:
Altitude(m)
Ambient temperature
℃
25
30
35
40
45
0
1
0.98
0.96
0.93
0.90
500
0.93
0.91
0.89
0.87
0.84
1000
0.87
0.85
0.82
0.80
0.78
2000
0.75
0.73
0.71
0.69
0.66
3000
0.64
0.62
0.60
0.58
0.56
4000
0.52
0.52
0.50
0.48
0.46
NOTE:
Relative humidity 60% correction factor C-0.01;
Relative humidity 80% correction factor C-0.02;
Relative humidity 90% correction factor C-0.03;
Relative humidity 100% correction factor C-0.04;
Example: Generator rated power P
N
=1.8kVA, Altitude:1000m,
Ambient temperature: 35
℃
, Relative humidity: 80%,
Actual power P:
P=P
N
*(C-0.02)=1.8*(0.82-0.02)=1.44kVA
Summary of Contents for SHP2000iE
Page 1: ...BEDIENUNGS ANLEITUNG Smart Inverter GENERATOR SHP2000iE VER2 6 20220112 ...
Page 13: ... 12 3 1 2 5 4 6 7 ...
Page 14: ... 13 7 ...
Page 66: ... 65 14 VERKABELUNGSDIAGRAMM SHP2000i ...
Page 67: ... 66 SHP2000iE ...
Page 69: ...Mehr Leistung Mehr Mobilität EASY POWER WITH YOU ...
Page 82: ... 81 3 1 2 5 4 6 7 ...
Page 83: ... 82 7 ...
Page 135: ... 134 14 WIRING DIAGRAM SHP2000i ...
Page 136: ... 135 SHP2000iE ...
Page 139: ......